Design requirements:
The general integrated prefabricated pumping station is designed according to the long-term scale, and the pump unit can be configured according to the recent scale. Because the sewage pumping station is easy to produce flammable, explosive and toxic and harmful gases during the pumping process, it must be designed as a separate building and take corresponding protective measures. Anti-corrosion measures should be taken for buildings and ancillary facilities of sewage pumping stations. The distance between the pumping station and the residential building and public buildings should be set separately to meet the requirements of the planning, fire protection and environmental protection departments. The shape of the ground building of the pumping station should be coordinated with the surrounding environment, so that it is applicable, economical and beautiful. The outdoor base elevation of the pumping station should be determined according to the urban flood control standard and meet the requirements of the planning department; the indoor floor of the pumping station should be higher than the outdoor floor 0.2-0.3m; for pumping stations that are vulnerable to flooded areas, the ground elevation of the entrance design should be more than 0.5m above the design flood level; when the above requirements are not met, temporary flood control measures such as gate grooves can be set at the entrance.
Advantage:
1. High internal system integration: the cylinder is made of advanced FRP material, internal submersible sewage pump, piping system, pulverizing grid, lifting device, intelligent control system and other accessories required by users.
2. Solving the problem of urban resource allocation: It is mainly embodied in the underground integrated pumping station, whose structure is coordinated with the surrounding environment and does not cause destructive power to urban buildings.
3. The engineering cycle is short, the floor space is small: the integrated pumping station factory is assembled, the installation time is much shorter than the traditional pump station.
4. Intelligent control system, users can experience the surprise brought by remote control.
5. High strength of the cylinder: the winding process and the application of the resin layer increase the strength of compression and corrosion resistance.
6. Low maintenance cost and long service life: it is about twice as long as the traditional pumping station.
Model meaning:
PPS 08 × 22 / 0.39 - 2 / SS
① ② ③ ④ ⑤ ⑥

1. Integrated prefabricated pumping station
2. Wellbore diameter
08=Φ800mm
10=Φ1000mm
12=Φ1200mm
20=Φ2000mm
38=Φ3800mm

3. Shaft height (length, depth): the height of the entire cylinder indicated (without accessories)
22=2200mm
25=2500mm
60=6000mm
130=13000mm
4.Pump station effective volume(m3)
5. The number of pump stations equipped with water pumps: 2 (can be equipped with 2-4 sets)
6. Material of the conveying pipe
Stainless steel 304SS, Carbon steel or Plastic pipe

Environment and working conditions:
·The ambient temperature should be -40 °C ~ 40 °C.
·The relative humidity is preferably 25% to 85%, and the anhydrous beads are condensed.
·The water medium delivered by the pumping station should meet the following requirements:
The temperature should be -5 °C ~ 70 °C;
PH value should be 4~10; (over-range use should be made at the time of ordering)
The maximum diameter of the particles in the conveying medium should be smaller than the diameter of the selected water pump.
·Power supply:
380V (±10%), 3-phase five-wire system, 50Hz (±5%);
220V (±10%), single phase, 50Hz (±5%).
·Vibration: <0.5g, vibration frequency 10Hz-50Hz maximum vibration acceleration should not exceed 5m / s2.
·The equipment operation location is generally applied to non-conductive or explosive dust (for occasions where the environment is required, please make an order when ordering, you can configure explosion-proof submersible pump (ExdI, ExdIIAT4, ExdIIBT4, ExdIICT4) or explosion-proof control cabinet, no corrosive metal or damage insulation gas or steam.
structure:
 

Performance parameter list : 

Model Staion Flow Pump flow Pump 5 min flow Start/close times effective volume Diameter liquid height height weight
m3/day M3/h M3/5min Times/h M3 m m m kg
PPS08X22/0.39-2 259 11 0.9 7 0.4 0.8 0.15 2.2 231
PPS08X22/0.54-2 360 15 1.3 7 0.5 0.8 0.21 2.2 231
PPS08X23/0.77-2 518 22 1.8 7 0.8 0.8 0.31 2.3 240
PPS08X24/0.90-2 605 29 2.1 7 0.9 0.8 0.36 2.4 248
PPS08X24/1.03-2 691 29 2.4 7 1.0 0.8 0.41 2.5 248
PPS08X25/1.29-2 864 36 3 7 1.3 0.8 0.51 2.5 254
PPS08X28/1.93-2 1296 54 4.5 7 1.9 0.8 0.77 2.8 278
PPS08X30/2.57-2 1728 72 6 7 2.6 0.8 1.02 3.0 295
PPS10X30/3.21-2 2160 90 7.5 7 3.2 1 1.02 3.0 386
PPS10X31/3.57-2 2402 100 8.3 7 3.6 1 1.14 3.1 396
PPS14X30/4.50-2 3024 126 10.5 7 4.5 1.4 1.02 3.0 531
PPS14X32/5.14-2 3456 144 12 7 5.1 1.4 1.17 3.2 556
PPS18X30/5.79-2 3888 162 13.5 7 5.8 1.8 1.02 3.0 712
PPS18X31/6.43-2 4320 180 15 7 6.4 1.8 1.14 3.1 729
PPS20X31/7.07-2 4752 198 16.5 7 7.1 2 1.13 3.1 1164
PPS30X40/19.29-2 12960 540 45 7 19.3 3 2.05 4.0 2385
PPS40X122/128.57-2 86400 3600 300 7 128.6 4 10.23 12.2 9002
For more specifications, please contact us.
 