Working principle and correct operation mode of integrated prefabricated pumping station

2020-06-10
The integrated prefabricated pump station is a device that gives power and pressure to the pump station through the power of the water pump, so that the liquid that cannot flow freely can be discharged and transported normally! The integrated prefabricated pumping station is a professional equipment used to enhance the absorption, discharge, and transportation of sewage, rainwater, wastewater, and drinking water.
So what is the working principle of the integrated prefabricated pumping station? How to use and operate the integrated prefabricated pumping station correctly?

The integrated prefabricated pump station mainly uses the water level pressure difference to control the start and stop of the pump. There are two ways to test the pressure difference. When the pressure difference sensor is intact, the pressure difference sensor is used to judge the water level to realize the pump start. And shut down, when the pressure difference sensor is damaged, the ordinary float is used to feedback the water level, and the pump is controlled to start and stop. 


 
In the use of the pumping station, the basket grille needs to be dredged and cleaned regularly. According to the different water flow, the crushing grille works. The crushing grille starts to break some magazines, and the sewage flows into the pumping station. The fence should be rested. This is because the sewage directly flows into the pump station and the impurities are blocked. When it is started again, the impurities will be broken.
Basket grilles need to be cleaned regularly, depending on the water flow. Crushing type grille, when working, the crushing grille starts to break some impurities, and the sewage flows into the pumping station. During the period, the smashing grid needs to be "rested". At this time, the sewage directly flows into the pump station and the impurities are blocked. When it is started again, the impurities will be broken. 

How does the sewage pump operate correctly?
The three sewage pumps work alternately. Two work and one rest. Take turns to rest. Work alternately. The water level cannot be higher than the maintenance platform.
The function of the vent above the pumping station is to prevent the harmful gas from exceeding the standard. Before the overhaul, discharge the gas to ensure the safety of the staff going down the well to work.